|
Building Pressurization Testing
Whole Building Pressurization Testing
We provide the design and implementation of
any type or size of building pressure testing:

-
We can assist the design professional or the owner in
developing the test specification and test parameters to
adhere to ASTM E779, ASTM E1827 or the Army Core of
Engineers Building Pressure testing guideline.
-
We provide a complete Testing Plan
that describes how
the building is to be testing, the testing parameters and
how the building needs to be prepared for the test.
-
We provide all required test gear including blower doors,
manometers.
We provide experienced certified testing technicians who
perform all test parameters and report the results of the
test.
-
We provide a complete report which indicates the test
compliance to the specified standard and shows the
associated math and log graphs of the test results to a 95%
certainty of accuracy.
Building pressure testing is normally done
immediately after the completion of all enclosure components and
all door sweeps and weather stripping is complete. It is
possible to provide a pre-test before the interior finishes
verifying the basic air barrier performance which requires
temporary sealing of any uncompleted doors or window spaces.
Water Intrusion Testing
Water intrusion testing is used to test the
building transition areas between walls, doors and windows for
water intrusion. The process sprays a calibrated stream of water
on the exterior of the area while the building is kept at a
negative pressure of 50 Pa.
-
1.
We can assist the design professional or the owner in
developing the test specification and test parameters to adhere
to by modification of ASTM E1105, AAMA 501.2 and AAMA 502.2
testing guidelines.
-
2.
We provide a complete Testing Plan that describes
how the building or mock ups are to be testing, the testing
parameters and how the building needs to be prepared for the
test.
-
3.
We provide all required test gear including blower doors,
manometers, wind velocity meters, spray nozzles and moisture
detectors.
-
4.
We provide experienced certified testing technicians who
perform all test parameters and report the results of the test
-
5.
We provide a complete report which indicates the test
compliance to the specified standard
Water intrusion testing is done after the
enclosure is complete, if possible before interior finishes are
complete.
Envelope Thermal Barrier Infrared
Testing
Thermal imaging is used to verify the
presence of air leaks, the effectives of the insulation
barrier or the presence of water intrusion.
-
We provide a testing plan that describes how the building
will be tested, the test parameters and how the building
needs to be prepared for the test.
-
We provide all required test gear including blower doors,
manometers, wind velocity meters, and thermal imaging
cameras.
-
We provide experienced certified testing technicians who
perform all test parameters and report the results of the
test.
-
We provide a complete report which indicates the test
compliance to the specified standard.
|